LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2017 >> CX-5 Grand Select, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 90 (Charging System - Engine) >> Battery Recharging [SKYACTIV-G 2.0, SKYACTIV-G 2.5] >> Without Using GR8-1291 (With i-ELOOP)

Without Using GR8-1291 (With i-ELOOP)

WARNING: This page is about a different car, the 2017 Mazda 3. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:
  • Remove the battery filler caps when recharging to prevent battery deformation or damage.
CAUTION:
  • After recharging, leave the battery as it is for as long as possible (6 hours or longer recommended) to dissipate the polarization in the battery.
  1. Remove the battery. (See BATTERY REMOVAL/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5] .)
    Fig 1: Removing Battery
    G09785419Courtesy of MAZDA MOTORS CORP.
  2. Remove the battery filler caps.
  3. To prevent loss of battery fluid during recharging, verify the battery fluid level.

    Battery fluid level is between upper and lower or less 

    • Add distilled water to the upper level.

      Battery fluid level is between upper and lower or more 

    • Go to the next step.
  4. Connect a battery recharger to the battery and adjust the charging current as follows.

    Constant current recharger device available 

    1. Apply a constant current charge so that the recharge current is 10 to 15 A. Perform the battery charge time referring to table (1).

      Battery recharge time (Table 1) 

    Cell with lowest electrolyte gravity 1.24 or more 1.23 1.22 1.21 1.20 1.19 1.18 1.17
    Charge time (min) 180 200 220 240 270 290 330 360

    No constant current recharger device available 

    1. Adjust the voltage so that the recharge current is 10 to 15 A. Verify the current after 30 s have elapsed since the measurement was started because the current is not stabilized after the voltage adjustment.
    2. Charge the battery for 60 min using current in step (1).
    3. Readjust the battery recharger so that the recharge current is 10 to 15 A.
    4. Charge the battery so that the total time for step (2) is the time in table (1).
  5. Measure electrolyte gravity of all cells.

    Cell with lowest electrolyte gravity is less than 1.25