DTC Table [Manual Air Conditioner]

WARNING: This page is about a different car, the 2016 Mazda CX-5. However, it is still accessible from the selected car via links, so may be relevant.

X: Applicable -: Not applicable

DTC No. Warning/indicator light System malfunction location Detected condition Fail-safe function Drive cycle Self test type(1) Memory function Refer To
B1086:71 - Airflow mode actuator Motor lock X - C X (See DTC B1086:71 [MANUAL AIR CONDITIONER] .)
B13AA:71 - Air mix actuator Motor lock X - C X (See DTC B13AA:71 [MANUAL AIR CONDITIONER] .)
B13AB:12 - Air mix actuator (potentiometer) Circuit short to ground X - C, D X (See DTC B13AB:12, B13AB:13 [MANUAL AIR CONDITIONER] .)
B13AB:13 -   Circuit open X - C, D X
B1B71:11 - Evaporator temperature sensor Circuit short to ground X - C, D X (See DTC B1B71:11, B1B71:13 [MANUAL AIR CONDITIONER] .)
B1B71:13 -   Circuit open X - C, D X
B1C1C:12 - Airflow mode actuator (potentiometer) Circuit short to ground X - C, D X (See DTC B1C1C:12, B1C1C:13 [MANUAL AIR CONDITIONER] .)
B1C1C:13 -   Circuit open X - C, D X
U0010:88 - CAN communication system Bus off X - C, D X (See DTC U0010:88, U0155:00 [MANUAL AIR CONDITIONER] .)
U0155:00 - Lost communication with instrument cluster No sub type information X - C X
U0423:68 - Invalid date received from Instrument cluster Event information X - C, D X (See DTC U0423:68 [MANUAL AIR CONDITIONER] .)
U200D:11 - Climate control unit circuit voltage (+5V) Circuit short to ground - - C, D X (See DTC U200D:11 [MANUAL AIR CONDITIONER] .)
U2300:54 - Configuration error Data not received X - C, D X (See DTC U2300:54, U2300:55, U2300:56, U2300:64 [MANUAL AIR CONDITIONER] .)
U2300:55 -   Not configured X - C, D -
U2300:56 -   Ineffective/non-interchangeable data read X - C, D X
U2300:64 -   Error value read X - C, D X
U3003:16 - Climate control unit power supply voltage Power supply voltage decreases (9.98 V or less)  - - C, D X (See DTC U3003:16, U3003:17 [MANUAL AIR CONDITIONER] .)
U3003:17 - Climate control unit power supply voltage Power supply voltage increases (16.21 V or more) - - C, D X
U300E:13 - Climate control unit power supply circuit open (IG2) Circuit open - - C, D X (See DTC U300E:13 [MANUAL AIR CONDITIONER] .)
(1) C: DTC self test, D: ODDTC self test