LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2017 >> CX-5 Grand Select, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 50 (On-Board Diagnostic - Engine Controls (2 Of 4)) >> DTC P0482-00: Cooling Fan Relay No. 2 And No. 3 Control Circuit Malfunction >> Diagnostic Procedure

Diagnostic Procedure

WARNING: This page is about a different car, the 2016 Mazda CX-5. However, it is still accessible from the selected car via links, so may be relevant.
STEP INSPECTION ACTION
1 VERIFY RELATED REPAIR INFORMATION AVAILABILITY 
  • Verify related Service Bulletins and/or on-line repair information availability.
  • Is any related repair information available?
Yes Perform repair or diagnosis according to the available repair information.
  • If the vehicle is not repaired, go to the next step.
No Go to the next step.
2 INSPECT COOLING FAN RELAY NO. 2 AND NO. 3 
  • Switch the ignition off.
  • Remove the cooling fan relay No. 2 and No. 3.
  • Inspect the cooling fan relay No. 2 and No. 3.

    (See RELAY INSPECTION .)

  • Is there any malfunction?
Yes Replace the cooling fan relay No. 2 and/or No. 3, then go to Step 8.
No Go to the next step.
3 INSPECT COOLING FAN RELAY NO. 2 AND NO. 3 POWER SUPPLY CIRCUIT FOR SHORT TO GROUND OR OPEN CIRCUIT 
  • Cooling fan relay No. 2 and No. 3 are removed.
  • Switch the ignition ON (engine off).
  • Measure the voltage at the following terminals (wiring harness-side):
    • Cooling fan relay No. 2 terminal A
    • Cooling fan relay No. 3 terminal A
  • Is the voltage B+  ?
Yes Go to the next step.
No Inspect the ENGINE3 15 A fuse.
  • If the fuse is blown:
    • Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
      • ENGINE3 15 A fuse-Cooling fan relay No. 2 terminal A
      • ENGINE3 15 A fuse-Cooling fan relay No. 3 terminal A

        If there is a common connector: 

        • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
        • Repair or replace the malfunctioning part.

        If there is no common connector: 

        • Repair or replace the wiring harness which has a short to ground.
    • Replace the fuse.
  • If the fuse is damaged:
    • Replace the fuse.
  • If the fuse is normal:
    • Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
      • Main relay terminal C- Cooling fan relay No. 2 terminal A
      • Main relay terminal C- Cooling fan relay No. 3 terminal A

        If there is a common connector: 

        • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
        • Repair or replace the malfunctioning part.

        If there is no common connector: 

        • Repair or replace the wiring harness which has an open circuit.

Go to Step 8.
4 INSPECT COOLING FAN RELAY NO. 2 AND NO. 3 SIGNAL CIRCUIT FOR SHORT TO GROUND 
  • Cooling fan relay No. 2 and No. 3 are removed.
  • Switch the ignition off.
  • Inspect for continuity between the following terminals (wiring harness-side) and body ground:
    • Cooling fan relay No. 2 terminal E
    • Cooling fan relay No. 3 terminal E
  • Is there continuity?
Yes If the short to ground circuit could be detected in the wiring harness:
  • Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
    • Cooling fan relay No. 2 terminal E-PCM terminal 2AV
    • Cooling fan relay No. 3 terminal E-PCM terminal 2AV

      If there is a common connector: 

    • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
    • Repair or replace the malfunctioning part.

      If there is no common connector: 

      • Repair or replace the wiring harness which has a short to ground.

If the short to ground circuit could not be detected in the wiring harness:


Go to Step 8.
No Go to the next step.
5 INSPECT PCM CONNECTOR CONDITION 
  • Disconnect the PCM connector.
  • Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
  • Is there any malfunction?
Yes Repair or replace the connector and/or terminals, then go to Step 8.
No Go to the next step.
6 INSPECT COOLING FAN RELAY NO. 2 AND NO. 3 SIGNAL CIRCUIT FOR SHORT TO POWER SUPPLY 
  • Cooling fan relay No. 2 and No. 3 are removed.
  • Verify that the PCM connector is disconnected.
  • Switch the ignition ON (engine off).
  • Measure the voltage at the following terminals (wiring harness-side):
    • Cooling fan relay No. 2 terminal E
    • Cooling fan relay No. 3 terminal E
  • Is the voltage 0 V  ?
Yes Go to the next step.
No Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
  • Cooling fan relay No. 2 terminal E-PCM terminal 2AV
  • Cooling fan relay No. 3 terminal E-PCM terminal 2AV

    If there is a common connector: 

    • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.
    • Repair or replace the malfunctioning part.

    If there is no common connector: 

    • Repair or replace the wiring harness which has a short to power supply.

Go to Step 8.
7 INSPECT COOLING FAN RELAY NO. 2 AND NO. 3 SIGNAL CIRCUIT FOR OPEN CIRCUIT 
  • Cooling fan relay No. 2 and No. 3 are removed.
  • Verify that the PCM connector is disconnected.
  • Switch the ignition off.
  • Inspect for continuity between the following terminals (wiring harness-side):
    • Cooling fan relay No. 2 terminal E-PCM terminal 2AV
    • Cooling fan relay No. 3 terminal E-PCM terminal 2AV
  • Is there continuity?
Yes Go to the next step.
No Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
  • Cooling fan relay No. 2 terminal E-PCM terminal 2AV
  • Cooling fan relay No. 3 terminal E-PCM terminal 2AV

    If there is a common connector: 

    • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
    • Repair or replace the malfunctioning part.

    If there is no common connector: 

    • Repair or replace the wiring harness which has an open circuit.

Go to the next step.
8 VERIFY DTC TROUBLESHOOTING COMPLETED  Yes Repeat the inspection from Step 1.
Go to the next step.
No Go to the next step.
9 VERIFY AFTER REPAIR PROCEDURE  Yes Go to the applicable DTC inspection.
(See DTC TABLE [SKYACTIV-G 2.0, SKYACTIV-G 2.5] .)
No DTC troubleshooting completed.