Step Inspection Action
1 INSPECT TCM CONNECTOR CONDITION 
Yes Go to the next step.
No Repair or replace the connector, then go to Step 6.
2 INSPECT START STOP UNIT CONNECTOR CONDITION 
  • Disconnect the start stop unit connector.
  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
  • Is the connector normal?
Yes Go to the next step.
No Repair or replace the connector, then go to Step 6.
3 INSPECT TCM CIRCUIT FOR SHORT TO GROUND 
  • Verify that the start stop unit and TCM connectors are disconnected.
  • Inspect for continuity between TCM terminal J (vehicle wiring harness side) and body ground.
  • Is there continuity?
Yes Repair or replace the wiring harness which is shorted to ground, then go to Step 6.
No Go to the next step.
4 INSPECT TCM CIRCUIT FOR OPEN CIRCUIT 
  • Verify that the start stop unit and TCM connectors are disconnected.
  • Inspect the wiring harness for continuity between start stop unit terminal 1F (vehicle wiring harness side) and TCM terminal J (vehicle wiring harness side).
  • Is there continuity?
Yes Go to the next step.
No Repair or replace the wiring harness which has an open circuit, then go to Step 6.
5 PERFORM DTC INSPECTION AND VERIFY IF MALFUNCTIONING PART IS TRANSAXLE RANGE SENSOR 
  • Reconnect all the disconnected connectors.
  • Reconnect the disconnected negative battery cable.

    (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5] .)

  • Clear DTC for the start stop unit using the M-MDS.

    (See CLEARING DTC [START STOP UNIT] .)

  • Switch the ignition ON (engine off).
  • Perform the following work five or more times.
    • Operate the selector lever to positions to other than P and N and wait for 1 s or more  .
    • Operate the selector lever to positions to P or N and wait for 1 s or more  .
    • Operate the selector lever to positions to other than P and N.
  • Perform the DTC inspection for the start stop unit using the M-MDS.

    (See DTC INSPECTION [START STOP UNIT] .)

  • Is DTC P0850:24 displayed?
Yes Replace the TCM, then go to the next step.
(See CONTROL VALVE BODY REMOVAL/INSTALLATION [FW6A-EL, FW6AX-EL] .)
No Go to Step 7.
6 VERIFY THAT REPAIRS HAVE BEEN COMPLETED 
  • Reconnect all the disconnected connectors.
  • Reconnect the disconnected negative battery cable.

    (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5] .)

  • Clear DTC for the start stop unit using the M-MDS.

    (See CLEARING DTC [START STOP UNIT] .)

  • Switch the ignition ON (engine off).
  • Perform the following work five or more times.
    • Operate the selector lever to positions to other than P and N and wait for 1 s or more  .
    • Operate the selector lever to positions to P or N and wait for 1 s or more  .
    • Operate the selector lever to positions to other than P and N.
  • Perform the DTC inspection for the start stop unit using the M-MDS.

    (See DTC INSPECTION [START STOP UNIT] .)

  • Is DTC P0850:24 displayed?
Yes Replace the start stop unit, then go to the next step.
(See START STOP UNIT REMOVAL/INSTALLATION .)
No Go to the next step.
7 VERIFY IF OTHER DTCs DISPLAYED 
  • Are any other DTCs displayed?
Yes Repair the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [START STOP UNIT] .)
No DTC troubleshooting completed.