Diagnostic Procedure
WARNING: This page is about a different car, the 2017 Mazda 3. However, it is still accessible from the selected car via links, so may be relevant.
AIR INTAKE MODE DOES NOT CHANGE (MANUAL AIR CONDITIONER) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 2* | INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR AIR INTAKE ACTUATOR
|
Yes | Go to Step 11. |
| No | Go to the next step. | ||
| 3 | INSPECT AIR INTAKE ACTUATOR CONNECTOR CONNECTION CONDITION
|
Yes | Go to the next step. |
| No | Reconnect the air intake actuator connector properly. Go to Step 13. |
||
| 4 | INSPECT AIR INTAKE ACTUATOR CONNECTOR TERMINAL CONDITION
|
Yes | Go to the next step. |
| No | Repair/replace the connector or terminal. Go to Step 13. |
||
| 5 | INSPECT AIR INTAKE ACTUATOR
|
Yes | Go to the next step. |
| No | Replace the air intake actuator, then go to Step 13. (See AIR INTAKE ACTUATOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER] .) |
||
| 6 | INSPECT CLIMATE CONTROL UNIT CONNECTOR CONNECTION CONDITION
|
Yes | Go to the next step. |
| No | Reconnect the climate control unit connector properly. Go to Step 13. |
||
| 7 | INSPECT CLIMATE CONTROL UNIT CONNECTOR TERMINAL CONDITION
|
Yes | Go to the next step. |
| No | Repair/replace the connector or terminal. Go to Step 13. |
||
| 8* | INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO POWER SUPPLY BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
|
Yes | Go to the next step. |
| No | Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal/evaporator temperature sensor terminal. If there is a common connector:
Go to Step 13. |
||
| 9* | INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO GROUND BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
|
Yes | Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal. If there is a common connector:
Go to Step 13. |
| No | Go to the next step. | ||
| 10* | INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY OR OPEN BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
|
Yes | Replace the climate control unit, then go to Step 13. (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER] .) |
| No | Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal. If there is a common connector:
Go to Step 13. |
||
| 11 | INSPECT AIR INTAKE LINK
|
Yes | Go to the next step. |
| No | Apply grease to the links. If any the links are damaged, replace the air intake actuator, then go to Step 13. (See BLOWER UNIT DISASSEMBLY/ASSEMBLY .) |
||
| 12 | INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR INTAKE DOOR
|
Yes | Go to the next step. |
| No | Remove obstruction, or install the doors in the proper position. If any doors are cracked or damaged, replace them, then go to the next step. | ||
| 13 | CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
|
Yes | Troubleshooting completed. Explain repairs to customer. |
| No | Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs. | ||