| 1 |
INSPECT IG1 RELAY
|
Yes |
Go to the next step. |
| No |
Replace the IG1 relay, then go to Step 6. (See RELAY LOCATION
.) |
| 2 |
INSPECT IG1 RELAY CIRCUIT FOR OPEN CIRCUIT OR SHORT TO GROUND
|
Yes |
Go to the next step. |
| No |
Inspect the MAIN 200 A fuse.
- If the fuse is blown:
- Refer to the wiring diagram and verify whether or not there is a common connector between MAIN 200 A fuse and IG1 relay terminal D.
If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has a short to ground.
- Replace the fuse.
- If the fuse is damaged:
- If the fuse is normal:
- Refer to the wiring diagram and verify whether or not there is a common connector between battery positive terminal and IG1 relay terminal D.
If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has an open circuit.
Go to Step 6. |
| 3 |
INSPECT START STOP UNIT CONNECTOR CONDITION
|
Yes |
Go to the next step. |
| No |
Repair or replace the connector, then go to Step 6. |
| 4 |
INSPECT IG1 RELAY CIRCUIT FOR SHORT TO GROUND
- Verify that the IG1 relay is removed.
- Verify that the start stop unit connector is disconnected.
- Inspect for continuity between the following terminals (wiring harness-side) and body ground:
- IG1 relay terminal C
- Start stop unit terminal 1B
- Is there continuity?
|
Yes |
Inspect the C/U IG1 15 A fuse.
- If the fuse is blown:
- Refer to the wiring diagram and verify whether or not there is a common connector between C/U IG1 15 A fuse and start stop unit terminal 1B.
If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has a short to ground.
- Replace the fuse.
- If the fuse is damaged:
- If the fuse is normal:
- Refer to the wiring diagram and verify whether or not there is a common connector between IG1 relay terminal C and C/U IG1 15 A fuse.
If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has a short to ground.
Go to Step 6. |
| No |
Go to the next step. |
| 5 |
INSPECT IG1 RELAY CIRCUIT FOR OPEN CIRCUIT
- Verify that the IG1 relay is removed.
- Verify that the start stop unit connector is disconnected.
- Inspect for continuity between IG1 relay terminal C (wiring harness-side) and start stop unit terminal 1B (wiring harness-side).
- Is there continuity?
|
Yes |
Go to the next step. |
| No |
Inspect the C/U IG1 15 A fuse.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has an open circuit.
Go to the next step. |
| 6 |
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes |
Repeat the inspection from Step 1. Go to the next step. |
| No |
Go to the next step. |
| 7 |
VERIFY IF OTHER DTCs DISPLAYED
- Are any other DTCs displayed?
|
Yes |
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [START STOP UNIT] .) |
| No |
DTC troubleshooting completed. |