Diagnostic procedure
DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | INSPECT FOR INSTRUMENT CLUSTER MALFUNCTION
|
Yes | Go to applicable DTC inspection. (See DTC TABLE [INSTRUMENT CLUSTER] .) |
| No | Go to the next step. | ||
| 2 | INSPECT TCS OFF SWITCH SIGNAL CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness, then go to Step 5. |
| No | Go to the next step. | ||
| 3 | INSPECT TCS OFF SWITCH SIGNAL CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness, then go to Step 5. | ||
| 4 | INSPECT TCS OFF SWITCH
|
Yes | Go to the next step. |
| No | Replace the TCS OFF switch, then go to the next step. (See TCS OFF SWITCH REMOVAL/INSTALLATION .) |
||
| 5 | VERIFY THAT THE SAME DTC IS NOT PRESENT
|
Yes | Repeat the inspection from Step 1. |
| No | Go to the next step. | ||
| 6 | VERIFY THAT NO OTHER DTCS ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [DYNAMIC STABILITY CONTROL (DSC)] .) |
| No | DTC troubleshooting completed. | ||