Step Inspection Action
1 VERIFY ALL SYSTEM DTCs
  • Switch the ignition off.
  • Switch the ignition ON (engine off or on) and wait for 10 s or more.
  • Perform a CMDTC self-test using the M-MDS. (See DTC INSPECTION [ELECTRIC PARKING BRAKE] .)
  • Are any DTCs other than DTC U300A:62 displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [ELECTRIC PARKING BRAKE] .)
No Go to the next step.
2 INSPECT ELECTRIC PARKING BRAKE CONTROL MODULE CONNECTOR CONDITION
  • Switch the ignition off.
  • Disconnect the negative battery terminal.

    (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)

  • Disconnect the electric parking brake control module connector.
  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
  • Is the connector normal?
Yes Go to the next step.
No Repair or replace the connector, then go to Step 4.
3 VERIFY ELECTRIC PARKING BRAKE CONTROL MODULE POWER SUPPLY (IG1) VOLTAGE
  • Connect the negative battery terminal.

    (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)

  • Switch the ignition ON (engine off or on).
  • Measure the voltage at the electric parking brake control module terminal 1AB (wiring harness-side).
  • Is the voltage B+?
Yes Go to the next step.
No Inspect the C/U IG1 15 A fuse.
  • If the fuse is blown:
    • Refer to the wiring diagram and verify whether or not there is a common connector between IG1 relay terminal C and electric parking brake control module terminal 1AB.

    If there is a common connector:

    • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
    • Repair or replace the malfunctioning part.

      If there is no common connector:

    • Repair or replace the wiring harness which has a short to ground.
    • Replace the fuse.
  • If the fuse is damaged:
    • Replace the fuse.
  • If the fuse is normal:
    • Refer to the wiring diagram and verify whether or not there is a common connector between IG1 relay terminal C and electric parking brake control module terminal 1AB.

    If there is a common connector:

    • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
    • Repair or replace the malfunctioning part.

      If there is no common connector:

    • Repair or replace the wiring harness which has an open circuit.

Go to the next step.
4 VERIFY THAT REPAIRS HAVE BEEN COMPLETED
  • Always reconnect all disconnected connectors.
  • Connect the negative battery terminal.

    (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)

  • Clear the DTC for the electric parking brake control module using the M-MDS.

    (See CLEARING DTC [ELECTRIC PARKING BRAKE] .)

  • Perform the following procedure 3 times or more.
    • Pull up the electric parking brake switch to operate the electric parking brake.
    • Press down the electric parking brake switch to release the electric parking brake.
  • Retrieve the electric parking brake control module DTCs using the M-MDS. (See DTC INSPECTION [ELECTRIC PARKING BRAKE] .)
  • Is the same DTC displayed?
Yes Repeat the inspection from Step 1.
Go to the next step.
No Go to the next step.
5 VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [ELECTRIC PARKING BRAKE] .)
No DTC troubleshooting completed.