Power Liftgate (PLG) Fully Open Position Reset
- Open the power liftgate (PLG).
- Press the power liftgate (PLG) opener switch for approx. 7 s.NOTE:
- Although the power liftgate (PLG) buzzer is activated two times after approx. 3 s, this does not indicate an improper procedure. Continue to press the switch.
- Verify that the power liftgate (PLG) buzzer is activated three times.