DTC U3004-16; ACC RELAY CIRCUIT MALFUNCTION DIAGNOSTIC PROCEDURE

Step Inspection Action
1 INSPECT ACC RELAY Yes Go to the next step.
No Replace the ACC relay, then go to Step 6.
(See RELAY LOCATION .)
2 INSPECT FOR OPEN CIRCUIT OR SHORT TO GROUND IN ACC RELAY CIRCUIT Yes Go to the next step.
No Inspect the IG2 30 A.
  • If the fuse is blown:
  • Refer to the wiring diagram and verify whether or not there is a common connector between IG2 30 A fuse and ACC relay terminal C.

If there is a common connector:
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
  • Repair or replace the malfunctioning part.

If there is no common connector:
  • Repair or replace the wiring harness which has a short to ground.
  • If the fuse is damaged:
  • Replace the fuse.
  • If the fuse is normal:
  • Refer to the wiring diagram and verify whether or not there is a common connector between battery positive terminal and ACC relay terminal C.

If there is a common connector:
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
  • Repair or replace the malfunctioning part.

If there is no common connector:
  • Repair or replace the wiring harness which has an open circuit.

Go to Step 6.
3 INSPECT START STOP UNIT CONNECTOR CONDITION
  • Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  • Disconnect the start stop unit connector.
  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
  • Is the connector normal?
Yes Go to the next step.
No Repair or replace the connector, then go to Step 6.
4 INSPECT FOR SHORT TO GROUND IN START STOP UNIT POWER SUPPLY CIRCUIT (ACC)
  • Verify that the ACC relay is removed.
  • Verify that the start stop unit connector is disconnected.
  • Inspect for continuity between the following terminals (wiring harness-side) and body ground:
    • ACC relay terminal D
      • Start stop unit terminal 1E
  • Is there continuity?
Yes Go to the next step.
No Inspect the MIRROR 7.5 A fuse.
  • If the fuse is blown:
  • Refer to the wiring diagram and verify whether or not there is a common connector between MIRROR 7.5 A fuse and start stop unit terminal 1E.

If there is a common connector:
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
  • Repair or replace the malfunctioning part.

If there is no common connector:
  • Repair or replace the wiring harness which has a short to ground.
  • If the fuse is damaged:
    • Replace the fuse.
    • If the fuse is normal:
      • Refer to the wiring diagram and verify whether or not there is a common connector between ACC relay terminal D and MIRROR 7.5 A fuse.

        If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
  • Repair or replace the malfunctioning part.

If there is no common connector:
  • Repair or replace the wiring harness which has a short to ground.

Go to Step 6.
5 INSPECT FOR OPEN CIRCUIT IN START STOP UNIT POWER SUPPLY CIRCUIT (ACC)
  • Verify that the ACC relay is removed.
  • Verify that the start stop unit connector is disconnected.
  • Inspect for continuity between ACC relay terminal D (wiring harness-side) and start stop unit terminal 1E (wiring harness-side).
  • Is the voltage B+?
Yes Go to the next step.
No Inspect the MIRROR 7.5 A fuse.
  • If the fuse is damaged:
    • Replace the fuse.
  • If the fuse is normal:
    • Refer to the wiring diagram and verify whether or not there is a common connector between ACC relay terminal D and start stop unit terminal 1E.

      If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
  • Repair or replace the malfunctioning part.

If there is no common connector:
  • Repair or replace the wiring harness which has an open circuit.

Go to the next step.
6 VERIFY THAT REPAIRS HAVE BEEN COMPLETED Yes Repeat the inspection from Step 1.
Go to the next step.
No Go to the next step.
7 VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [START STOP UNIT] .)
No DTC troubleshooting completed.