Diagnostic Procedure
DTC U3004-12; ACC RELAY CIRCUIT MALFUNCTION DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT ACC RELAY
|
Yes | Go to the next step. |
| No | Replace the ACC relay, then go to Step 4. (See RELAY LOCATION .) |
||
| 2 | INSPECT START STOP UNIT CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 4. | ||
| 3 | INSPECT FOR SHORT TO POWER SUPPLY IN ACC RELAY CIRCUIT
|
Yes | Refer to the wiring diagram and verify whether or not there is a common connector between ACC relay terminal E and start stop unit terminal 2C. If there is a common connector:
If there is no common connector:
|
| No | Go to the next step. | ||
| 4 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
|
| No | Go to the next step. | ||
| 5 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [START STOP UNIT] .) |
| No | DTC troubleshooting completed. | ||