LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2017 >> CX-5 Grand Select, FWD >> Repair and Diagnosis >> Body & Frame >> Door Locks >> On-Board Diagnostic - Start Stop Unit >> DTC U201F-12; Keyless Receiver Circuit Malfunction >> Diagnostic Procedure

Diagnostic Procedure

DTC U201F-12; KEYLESS RECEIVER CIRCUIT MALFUNCTION DIAGNOSTIC PROCEDURE

Step Inspection Action
1 INSPECT KEYLESS RECEIVER CONNECTOR CONDITION
  • Switch the ignition off.
  • Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  • Disconnect the keyless receiver connector.
  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
  • Is the connector normal?
Yes Go to the next step.
No Repair or replace the connector, then go to Step 5.
2 INSPECT START STOP UNIT CONNECTOR CONDITION
  • Disconnect the start stop unit connector.
  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
  • Is the connector normal?
Yes Go to the next step.
No Repair or replace the connector, then go to Step 5.
3 INSPECT KEYLESS RECEIVER CIRCUIT FOR SHORT TO POWER SUPPLY
  • Reconnect the start stop unit connector.
  • Verify that the keyless receiver connector is disconnected.
  • Connect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  • Switch the ignition ON (engine off or on).
  • Measure the voltage at the following terminals (wiring harness-side):
    • Keyless receiver terminal A
      • Start stop unit terminal 2Q
  • Is the voltage 0 V?
Yes Go to the next step.
No Refer to the wiring diagram and verify whether or not there is a common connector between start stop unit terminal 2Q and keyless receiver terminal A.
If there is a common connector:
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.
  • Repair or replace the malfunctioning part.

If there is no common connector:
  • Repair or replace the wiring harness which has a short to power supply.

Go to Step 5.
4 INSPECT KEYLESS RECEIVER Yes Go to the next step.
No Replace the keyless receiver, then Go to the next step.
(See KEYLESS RECEIVER REMOVAL/INSTALLATION .)
5 VERIFY THAT REPAIRS HAVE BEEN COMPLETED Yes Repeat the inspection from Step 1.
No Go to the next step.
6 VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [START STOP UNIT] .)
No DTC troubleshooting completed.