LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2017 >> CX-5 Grand Select, FWD >> Repair and Diagnosis >> Body & Frame >> Door Locks >> On-Board Diagnostic - Start Stop Unit >> DTC B10E7-16; IG1 Relay Circuit Malfunction >> Diagnostic Procedure

Diagnostic Procedure

DTC B10E7-16; IG1 RELAY CIRCUIT MALFUNCTION - DIAGNOSTIC PROCEDURE

Step Inspection Action
1 INSPECT IG1 RELAY Yes Go to the next step.
No Replace the IG1 relay, then go to Step 6.
(See RELAY LOCATION .)
2 INSPECT IG1 RELAY CIRCUIT FOR OPEN CIRCUIT OR SHORT TO GROUND Yes Go to the next step.
No Inspect the MAIN 200 A fuse.
  • If the fuse is blown:
    • Refer to the wiring diagram and verify whether or not there is a common connector between MAIN 200 A fuse and IG1 relay terminal D.

    If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
    • Repair or replace the malfunctioning part.

    If there is no common connector:

  • Repair or replace the wiring harness which has a short to ground.
    • Replace the fuse.
    • If the fuse is damaged:
      • Replace the fuse.
  • If the fuse is normal:
    • Refer to the wiring diagram and verify whether or not there is a common connector between battery positive terminal and IG1 relay terminal D.

      If there is a common connector:

    • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
      • Repair or replace the malfunctioning part.

        If there is no common connector:

      • Repair or replace the wiring harness which has an open circuit.

Go to Step 6.
3 INSPECT START STOP UNIT CONNECTOR CONDITION
  • Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  • Disconnect the start stop unit connector.
  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
  • Is the connector normal?
Yes Go to the next step.
No Repair or replace the connector, then go to Step 6.
4 INSPECT IG1 RELAY CIRCUIT FOR SHORT TO GROUND
  • Verify that the IG1 relay is removed.
  • Verify that the start stop unit connector is disconnected.
  • Inspect for continuity between the following terminals (wiring harness-side) and body ground:
    • IG1 relay terminal C
      • Start stop unit terminal 1B
  • Is there continuity?
Yes Inspect the C/U IG1 15 A fuse.
  • If the fuse is blown:
    • Refer to the wiring diagram and verify whether or not there is a common connector between C/U IG1 15 A fuse and start stop unit terminal 1B.

    If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
    • Repair or replace the malfunctioning part.

    If there is no common connector:

  • Repair or replace the wiring harness which has a short to ground.
    • Replace the fuse.
    • If the fuse is damaged:
      • Replace the fuse.

Go to Step 6.
No Go to the next step.
5 INSPECT IG1 RELAY CIRCUIT FOR OPEN CIRCUIT
  • Verify that the IG1 relay is removed.
  • Verify that the start stop unit connector is disconnected.
  • Inspect for continuity between IG1 relay terminal C (wiring harness-side) and start stop unit terminal 1B (wiring harness-side).
  • Is there continuity?
Yes Go to the next step.
No Inspect the C/U IG1 15 A fuse.
  • If the fuse is damaged:
    • Replace the fuse.
  • If the fuse is normal:
    • Refer to the wiring diagram and verify whether or not there is a common connector between IG1 relay terminal C and start stop unit terminal 1B.

      If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
    • Repair or replace the malfunctioning part.

      If there is no common connector:

    • Repair or replace the wiring harness which has an open circuit.

Go to the next step.
6 VERIFY THAT REPAIRS HAVE BEEN COMPLETED Yes Repeat the inspection from Step 1.
Go to the next step.
No Go to the next step.
7 VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [START STOP UNIT] .)
No DTC troubleshooting completed.