Diagnostic Procedure
DTC B10E7-16; IG1 RELAY CIRCUIT MALFUNCTION - DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT IG1 RELAY
|
Yes | Go to the next step. |
| No | Replace the IG1 relay, then go to Step 6. (See RELAY LOCATION .) |
||
| 2 | INSPECT IG1 RELAY CIRCUIT FOR OPEN CIRCUIT OR SHORT TO GROUND
|
Yes | Go to the next step. |
| No | Inspect the MAIN 200 A fuse.
Go to Step 6. |
||
| 3 | INSPECT START STOP UNIT CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 6. | ||
| 4 | INSPECT IG1 RELAY CIRCUIT FOR SHORT TO GROUND
|
Yes | Inspect the C/U IG1 15 A fuse.
Go to Step 6. |
| No | Go to the next step. | ||
| 5 | INSPECT IG1 RELAY CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Inspect the C/U IG1 15 A fuse.
Go to the next step. |
||
| 6 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
Go to the next step. |
| No | Go to the next step. | ||
| 7 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [START STOP UNIT] .) |
| No | DTC troubleshooting completed. | ||