Diagnostic Procedure
NOTE:
- The malfunction may be caused by a non-genuine, after-market electrical component. If a non-genuine, after-market electrical component has been installed and it cannot be determined whether the malfunction cause is due to the non-genuine, after-market electrical component or not, more time may be required to perform the malfunction diagnosis. (See FOREWORD [ENTERTAINMENT SYSTEM [WITH CENTER DISPLAY]] .)
VOICE OPERATION NOT POSSIBLE (ENTERTAINMENT SYSTEM - WITH CENTER DISPLAY) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | VERIFY AFTER-MARKET ELECTRICAL COMPONENT INSTALLATION CONDITION
|
Yes | Go to the next step. |
| No | Go to Step 3. | ||
| 2 | VERIFY IF MALFUNCTION CAUSE IS AFTER-MARKET ELECTRICAL COMPONENT INSTALLATION
|
Yes | Go to the next step. |
| No | Explain to the customer that the malfunction occurred due to the after-market electrical component installation. | ||
| 3 | VERIFY IF MALFUNCTION DUE TO CUSTOMER USE METHOD
|
Yes | System is normal. (Explain the contents of the servicing to the customer) |
| No | Go to the next step. | ||
| 4 | VERIFY IF MALFUNCTION DUE TO EFFECTS OF SURROUNDING ENVIRONMENT
|
Yes | System is normal. (Explain the contents of the servicing to the customer) |
| No | Go to the next step. | ||
| 5 | DETERMINE IF MALFUNCTION IS SPEAKER, AUDIO AMPLIFIER RELATED
|
Yes | The speakers and audio amplifier are normal. Go to the next step. |
| No | Perform malfunction diagnosis according to NO SOUND OUTPUT IN ALL MODES. (See NO SOUND OUTPUT IN ALL MODES [ENTERTAINMENT SYSTEM [WITH CENTER DISPLAY]] .) |
||
| 6 | DETERMINE IF MALFUNCTION IS TAU
|
Yes | TAU is normal. Go to the next step. |
| No | Perform malfunction diagnosis according to NO SOUND OUTPUT IN MULTIPLE MODES. (See NO SOUND OUTPUT IN MULTIPLE MODES [ENTERTAINMENT SYSTEM [WITH CENTER DISPLAY]] .) |
||
| 7 | DETERMINE IF MALFUNCTION IS MICROPHONE RELATED
|
Yes | The microphone is normal. Go to Step 12. |
| No | Go to the next step. | ||
| 8 | MICROPHONE CONNECTOR INSPECTION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 13. | ||
| 9 | VERIFY IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN CMU AND MICROPHONE
|
Yes | Go to the next step. |
| No |
|
||
| 10 | VERIFY IF MALFUNCTION CAUSE IS SHORT CIRCUIT TO GROUND IN WIRING HARNESS BETWEEN CMU AND MICROPHONE
|
Yes |
|
| No | Go to the next step. | ||
| 11 | VERIFY IF MALFUNCTION CAUSE IS SHORT CIRCUIT TO POWER SUPPLY IN WIRING HARNESS BETWEEN CMU AND MICROPHONE
|
Yes |
|
| No | Replace the microphone, then go to Step 13. (See MICROPHONE REMOVAL/INSTALLATION .) |
||
| 12 | INSPECT CMU CONNECTOR
|
Yes | Replace the CMU, then go to the next step. (See CONNECTIVITY MASTER UNIT (CMU) REMOVAL/INSTALLATION .) |
| No | Repair or replace the connector, then go to the next step. | ||
| 13 | VERIFY IF MALFUNCTION CAUSE IS CORRECTED
|
Yes | Troubleshooting completed. (Explain the contents of the servicing to the customer.) |
| No | Verify the malfunction symptom in the symptom troubleshooting chart and perform the other applicable malfunction diagnosis. (See SYMPTOM TROUBLESHOOTING [ENTERTAINMENT SYSTEM [WITH CENTER DISPLAY]] .) |
||