Diagnostic Procedure
IMAGE NOT OUTPUT IN ALL MODES (ENTERTAINMENT SYSTEM - WITH CENTER DISPLAY) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT CENTER DISPLAY CONNECTOR
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 5. | ||
| 2 | INSPECT CMU CONNECTOR
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 5. | ||
| 3 | VERIFY IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN CENTER DISPLAY AND BODY GROUND
|
Yes | Go to the next step. |
| No |
|
||
| 4 | VERIFY IF MALFUNCTION CAUSE IS CENTER DISPLAY
|
Yes | Go to the next step. |
| No | Replace the CMU, then go to the next step. (See CONNECTIVITY MASTER UNIT (CMU) REMOVAL/INSTALLATION .) |
||
| 5 | VERIFY IF MALFUNCTION CAUSE IS CORRECTED
|
Yes | Troubleshooting completed (explain the contents of the servicing to the customer). |
| No | Verify the malfunction symptom in the symptom troubleshooting chart and perform the other applicable malfunction diagnosis. (See SYMPTOM TROUBLESHOOTING [ENTERTAINMENT SYSTEM [WITH CENTER DISPLAY]] .) |
||