Diagnostic procedure
BLIND SPOT MONITORING (BSM) WARNING ALARM DOES NOT SOUND WHILE BLIND SPOT MONITORING (BSM) WARNING LIGHT FLASHES (BLIND SPOT MONITORING (BSM) SYSTEM) DIAGNOSTIC PROCEDURE
| Step | Inspection | Result | Action |
|---|---|---|---|
| 1 | VERIFY MALFUNCTION SYMPTOM
|
Yes | Go to Step 3. |
| No | Go to the next step. | ||
| 2 | INSPECT BLIND SPOT MONITORING (BSM) WARNING ALARM REQUEST SIGNAL
|
Yes | Replace the applicable blind spot monitoring (BSM) control module. (See BLIND SPOT MONITORING (BSM) CONTROL MODULE REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 3 | DETERMINE IF MALFUNCTION CAUSE IS BLIND SPOT MONITORING (BSM) CONTROL MODULE OR INSTRUMENT CLUSTER
|
Yes | Replace the applicable blind spot monitoring (BSM) control module. (See BLIND SPOT MONITORING (BSM) CONTROL MODULE REMOVAL/INSTALLATION .) |
| No | Replace the instrument cluster. (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .) |