Diagnostic procedure
BLIND SPOT MONITORING (BSM) OFF INDICATOR LIGHT DOES NOT ILLUMINATE WHEN IGNITION SWITCHED TO ON (BLIND SPOT MONITORING (BSM) SYSTEM) DIAGNOSTIC PROCEDURE
| Step | Inspection | Result | Action |
|---|---|---|---|
| 1* | INSPECT BLIND SPOT MONITORING (BSM) CONTROL MODULE (RH) POWER SUPPLY VOLTAGE
|
Yes | Go to the next step. |
| No | Inspect and repair for the following:
|
||
| 2* | INSPECT BLIND SPOT MONITORING (BSM) CONTROL MODULE (RH) GROUND CIRCUIT
|
Yes | Go to the next step. |
| No | Inspect and repair the ground point. Repair or replace for an open circuit between the blind spot monitoring (BSM) control module (RH) and ground. |
||
| 3 | INSPECT IF MALFUNCTION IS IN INSTRUMENT CLUSTER OR BLIND SPOT MONITORING (BSM) CONTROL MODULE (RH)
|
Yes | Replace the blind spot monitoring (BSM) control module. (See BLIND SPOT MONITORING (BSM) CONTROL MODULE REMOVAL/INSTALLATION .) |
| No | Replace the instrument cluster. (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .) |