LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2017 >> CX-5 Grand Select, FWD >> Repair and Diagnosis >> Accessories & Equipment >> Communication Devices >> On-Board Diagnostic - Power Liftgate Control Module >> DTC U3006-13; Power Supply Circuit Malfunction >> Diagnostic Procedure

Diagnostic Procedure

DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 VERIFY PCM DTCs Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [PCM (SKYACTIV-G 2.0, SKYACTIV-G 2.5)] .)
No Go to the next step.
2 INSPECT BATTERY Yes Go to the next step.
No Recharge or replace the battery, then go to Step 6.
(See BATTERY RECHARGING .)
(See BATTERY REMOVAL/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5] .)
3 INSPECT GENERATOR Yes Go to the next step.
No Replace the generator, then go to Step 6.
(See GENERATOR REMOVAL/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5] .)
4 INSPECT POWER LIFTGATE (PLG) CONTROL MODULE CONNECTOR CONDITION
  • Switch the ignition off.
  • Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  • Disconnect the power liftgate (PLG) control module connector.
  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
  • Is the connector normal?
Yes Go to the next step.
No Repair or replace the connector, then go to Step 6.
5 VERIFY POWER LIFTGATE (PLG) CONTROL MODULE POWER SUPPLY VOLTAGE
  • Always reconnect all disconnected connectors.
  • Connect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  • Measure the voltage at the power liftgate (PLG) control module terminal 2I (wiring harness-side).
  • Is the voltage B+?
Yes Go to the next step.
No Inspect the PLG 20 A fuse and CABIN.+B 50 A fuse.
  • Any fuse is blown:
  • Refer to the wiring diagram and verify whether or not there is a common connector between MAIN 200 A fuse and power liftgate (PLG) control module terminal 2I.

    If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
    • Repair or replace the malfunctioning part.

    If there is no common connector:

  • Repair or replace the wiring harness which has a short to ground.
    • Replace the fuse.
    • Any fuse is damaged:
    • Replace the fuse.
  • All fuses are normal:
  • Refer to the wiring diagram and verify whether or not there is a common connector between battery positive terminal and power liftgate (PLG) control module terminal 2I.

    If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
    • Repair or replace the malfunctioning part.

    If there is no common connector:

    • Repair or replace the wiring harness which has an open circuit.

    Go to the next step.

6 VERIFY THAT REPAIRS HAVE BEEN COMPLETED Yes Repeat the inspection from Step 1.
No Go to the next step.
7 VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [POWER LIFTGATE (PLG) CONTROL MODULE] .)
No DTC troubleshooting completed.