DTC B113E-12; Power Liftgate (PLG) Rear Switch Circuit Malfunction: Notes
DETECTION CONDITION AND POSSIBLE CAUSES
| Description |
Power liftgate (PLG) rear switch circuit malfunction |
| Detection condition |
- Power liftgate (PLG) control module detects a short to power supply in the power liftgate (PLG) rear switch circuit.
|
| Fail-safe |
- Stops the power liftgate (PLG) system operation.
|
| Possible cause |
- Power liftgate (PLG) rear switch connector or terminal malfunction
- Power liftgate (PLG) rear switch malfunction
- Power liftgate (PLG) control module connector or terminal malfunction
- Short to power supply in wiring harness between power liftgate (PLG) rear switch terminal C and power liftgate (PLG) control module terminal 1AF