Inspection item
- Connectors C-72, C-73
- Connector C-16
- Connector C-19
- Connector C-64
- Wiring harness between connectors C-72, C-73 and connector C-16
- Wiring harness between connector C-16 and connector C-19
- Wiring harness between connector C-19 and connector C-19
- Wiring harness between connector C-19 and connector C-64
S
- Forward sensing camera (FSC) power supply voltage-related wiring harness and fuse
- Forward sensing camera (FSC) body ground related wiring harness
- Forward sensing camera (FSC) connector
- Wiring harness between forward sensing camera (FSC) terminal M and branch B
- Wiring harness between forward sensing camera (FSC) terminal N and branch B
- Forward sensing camera (FSC)
T
- Connector C-19
- Connector C-64
- Wiring harness between branch B and connector C-19
- Wiring harness between connector C-19 and connector C-64
U
- Start stop unit power supply voltage-related wiring harness and fuse
- Start stop unit body ground related wiring harness
- Start stop unit connector
- Connector C-64
- Wiring harness between start stop unit terminal 2M and connector C-64
- Wiring harness between start stop unit terminal 2O and connector C-64
- Start stop unit
V
- EPS control module power supply voltage-related wiring harness and fuse
- EPS control module body ground related wiring harness
- EPS control module connector
- Connector C-64
- Wiring harness between EPS control module terminal 2B and connector C-64
- Wiring harness between EPS control module terminal 2D and connector C-64
- EPS control module
W
- Connector C-64
- Connector C-63
- Wiring harness between connector C-64 and connector C-63
X
WARNING:
- Handling the component parts of the SRS air bag system improperly can accidentally operate (deploy) the air bag module, which may seriously injure you. Read the service warnings and cautions before handling the air bag system components of the SRS air bag system. (See AIR BAG SYSTEM SERVICE WARNINGS [STANDARD DEPLOYMENT CONTROL SYSTEM - MEXICO SPEC.] .) (See AIR BAG SYSTEM SERVICE WARNINGS [TWO-STEP DEPLOYMENT CONTROL SYSTEM - US/CANADA SPEC.] .) (See AIR BAG SYSTEM SERVICE CAUTIONS [STANDARD DEPLOYMENT CONTROL SYSTEM - MEXICO SPEC.] .) (See AIR BAG SYSTEM SERVICE CAUTIONS [TWO-STEP DEPLOYMENT CONTROL SYSTEM - US/CANADA SPEC.] .)
- SAS control module power supply voltage-related wiring harness and fuse
- SAS control module body ground related wiring harness
- SAS control module connector
- Connector C-63
- Wiring harness between SAS control module terminal 3Q and connector C-63
- Wiring harness between SAS control module terminal 3S and connector C-63
- SAS control module
Y
- Connectivity master unit (CMU) power supply voltage-related wiring harness and fuse
- Connectivity master unit (CMU) body ground related wiring harness
- Connectivity master unit (CMU) connector
- Connector C-63
- Wiring harness between connectivity master unit (CMU) terminal 2E and connector C-63
- Wiring harness between connectivity master unit (CMU) terminal 2F and connector C-63
- Connectivity master unit (CMU)
Z