Diagnostic procedure
NO. 1 ANY OF FOLLOWING LIGHTS DO NOT ILLUMINATE WITH IGNITION ON DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY WHERE MALFUNCTION IS IN WARNING LIGHTS AND INDICATOR LIGHTS' COMMON POWER SUPPLY, OR IN OTHER WARNING LIGHTS AND INDICATOR LIGHTS
|
Yes | Go to Step 5. |
| No | If communication error message is displayed on the M-MDS (IDS) screen:
If communication error message is not displayed:
|
||
| 2 | INSPECT INSTRUMENT CLUSTER POWER SUPPLY FUSE
|
Yes | Go to the next step. |
| No | Inspect the blown fuse's circuit for short to ground. Repair or replace the wiring harness for a possible short to ground as necessary. Install appropriate amperage fuse. |
||
| *3 | VERIFY WHETHER MALFUNCTION IS IN WIRING HARNESS (BETWEEN INSTRUMENT CLUSTER POWER SUPPLY AND INSTRUMENT CLUSTER FOR CONTINUITY) OR ELSEWHERE
|
Yes | Go to the next step. |
| No | Inspect for open circuit between instrument cluster and ignition. Repair or replace the wiring harness for a possible open circuit as necessary. |
||
| *4 | VERIFY WHETHER MALFUNCTION IS IN WIRING HARNESS (BETWEEN INSTRUMENT CLUSTER AND GROUND FOR CONTINUITY) OR INSTRUMENT CLUSTER
|
Yes | Replace the instrument cluster. (Open circuit in the instrument cluster) (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .) |
| No | Repair or replace the wiring harness for a possible open circuit and poor contact in GND point. | ||
| 5 | CONFIRM DSC HU/CM DTC
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [DYNAMIC STABILITY CONTROL (DSC)] .) |
| No | If communication error message is displayed on the M-MDS (IDS) screen:
|
||
| 6 | INSPECT DSC HU/CM POWER SUPPLY FUSE
|
Yes | Go to the next step. |
| No | Inspect the blown fuse's circuit for short to ground. Repair or replace the wiring harness for a possible short to ground as necessary. Install appropriate amperage fuse. |
||
| *7 | VERIFY WHETHER MALFUNCTION IS IN WIRING HARNESS (BETWEEN DSC HU/CM POWER SUPPLY AND DSC HU/CM FOR CONTINUITY) OR ELSEWHERE
|
Yes | Go to the next step. |
| No | Inspect for open circuit between DSC HU/CM and ignition. Repair or replace the wiring harness for a possible open circuit as necessary. |
||
| *8 | VERIFY WHETHER MALFUNCTION IS IN WIRING HARNESS (BETWEEN DSC HU/CM AND GROUND FOR CONTINUITY) OR ELSEWHERE
|
Yes | Replace the DSC HU/CM. (Open circuit in the DSC HU/CM) (See DSC HU/CM REMOVAL/INSTALLATION .) |
| No | Repair or replace the wiring harness for a possible open circuit and poor contact in GND point. | ||
| 9 | CONFIRM INSTRUMENT CLUSTER DTC
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [INSTRUMENT CLUSTER] .) |
| No | Replace the instrument cluster. (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .) |
||
- When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while doing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, check to make sure connectors, terminals and wiring harness are connected correctly and undamaged.