Diagnostic procedure
BLIND SPOT MONITORING (BSM) WARNING LIGHT DOES NOT FLASH OR ILLUMINATE CONTINUOUSLY, BUT A TURN SIGNAL ON (BLIND SPOT MONITORING (BSM) SYSTEM) DIAGNOSTIC PROCEDURE
| Step | Inspection | Result | Action |
|---|---|---|---|
| 1 | INSPECT BLIND SPOT MONITORING (BSM) WARNING ALARM
|
Yes | Go to the next step. |
| No | Replace the instrument cluster. (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .) |
||
| 2 | VERIFY DTCs
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [INSTRUMENT CLUSTER] .) (See DTC TABLE [BLIND SPOT MONITORING (BSM) CONTROL MODULE] .) |
| No | Go to the next step. | ||
| 3 | VERIFY BLIND SPOT MONITORING (BSM) WARNING LIGHT CONDITION
|
Yes | Replace the blind spot monitoring (BSM) control module. (See BLIND SPOT MONITORING (BSM) CONTROL MODULE REMOVAL/INSTALLATION .) |
| No | Go to the symptom troubleshooting procedure, "blind spot monitoring (BSM) warning light does not illuminate while under blind spot monitoring (BSM) warning light-illumination conditions". (See BLIND SPOT MONITORING (BSM) WARNING LIGHT DOES NOT ILLUMINATE WHILE UNDER BLIND SPOT MONITORING (BSM) WARNING LIGHT-ILLUMINATION CONDITIONS [BLIND SPOT MONITORING (BSM) SYSTEM] .) |