Diagnostic procedure
NO. 6 INSTRUMENT CLUSTER BACK-UP LIGHT DOES NOT DIM WHEN TAILLIGHTS ILLUMINATE (INSTRUMENT CLUSTER) DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 |
|
Yes | Troubleshooting completed. (The system is normal.) |
| No | Go to the next step. | ||
| 2 |
|
Yes | Go to the next step. |
| No | Inspect and repair parts and the wiring harness which are related to the following light switch.
|
||
| 3 |
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE
.) (See DTC TABLE [BCM] .) |
| No | Replace the instrument cluster. (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .) |
||