Continuity Inspection
- Disconnect the negative battery terminal. (Refer to NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
- Disconnect the wastegate valve actuator connector. (Refer to DYNAMIC PRESSURE TURBO REMOVAL/INSTALLATION .)
- Inspect for continuity between wastegate valve actuator terminals B and F.
- If there is no continuity, replace the dynamic pressure turbo. (Refer to DYNAMIC PRESSURE TURBO REMOVAL/INSTALLATION .)