DTC Table
X: Applicable-: Not applicable
| DTC No. |
Warning/indicator light |
System malfunction location |
Detected condition |
Fail-safe function |
Drive cycle |
Self test type |
Memory function |
Page |
| B1086:71 |
- |
Airflow mode actuator |
Motor lock |
X |
- |
C |
X |
(See DTC B1086:71 [MANUAL AIR CONDITIONER] .) |
| B13AA:71 |
- |
Air mix actuator |
Motor lock |
X |
- |
C |
X |
(See DTC B13AA:71 [MANUAL AIR CONDITIONER] .) |
| B13AB:12 |
- |
Air mix actuator (potentiometer) |
Circuit short to power supply |
X |
- |
C, D |
X |
(See DTC B13AB:12, B13AB:13 [MANUAL AIR CONDITIONER] .) |
| B13AB:13 |
- |
Circuit open |
X |
- |
C, D |
X |
| B1B71:11 |
- |
Evaporator temperature sensor |
Circuit short to ground |
X |
- |
C, D |
X |
(See DTC B1B71:11, B1B71:13 [MANUAL AIR CONDITIONER] .) |
| B1B71:13 |
- |
Circuit open |
X |
- |
C, D |
X |
| B1C1C:12 |
- |
Airflow mode actuator (potentiometer) |
Circuit short to power supply |
X |
- |
C, D |
X |
(See DTC B1C1C:12, B1C1C:13 [MANUAL AIR CONDITIONER] .) |
| B1C1C:13 |
- |
Circuit open |
X |
- |
C, D |
X |
| U0010:88 |
- |
CAN communication system |
Bus off |
X |
- |
C |
X |
(See DTC U0010:88, U0155:00 [MANUAL AIR CONDITIONER] .) |
| U0155:00 |
- |
Lost communication with instrument cluster |
No sub type information |
X |
- |
C, D |
X |
| U0423:68 |
- |
Invalid date received from Instrument cluster |
Event information |
X |
- |
C, D |
X |
(See DTC U0423:68 [MANUAL AIR CONDITIONER] .) |
| U200D:11 |
- |
Climate control unit circuit voltage (+5V) |
Circuit short to ground |
- |
- |
C, D |
X |
(See DTC U200D:11 [MANUAL AIR CONDITIONER] .) |
| U2300:54 |
- |
Configuration error |
Data not received |
X |
- |
C, D |
X |
(See DTC U2300:54, U2300:55, U2300:56, U2300:64 [MANUAL AIR CONDITIONER] .) |
| U2300:55 |
- |
Not configured |
X |
- |
C, D |
- |
| U2300:56 |
- |
Ineffective/non-interchangeable data read |
X |
- |
C, D |
X |
| U2300:64 |
- |
Error value read |
X |
- |
C, D |
X |
| U3003:16 |
- |
Climate control unit power supply voltage |
Power supply voltage decreases (10 V or less
) |
- |
- |
C, D |
X |
(See DTC U3003:16, U3003:17 [MANUAL AIR CONDITIONER] .) |
| U3003:17 |
- |
Climate control unit power supply voltage |
Power supply voltage increases (17.3 V or more
) |
- |
- |
C, D |
X |