LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2016 >> 6 Touring, Standard Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> On-Board Diagnostics - Manual A/C >> DTC Table

DTC Table

X: Applicable-: Not applicable

DTC No. Warning/indicator light System malfunction location Detected condition Fail-safe function Drive cycle Self test type(1) Memory function Page
B1086:71 - Airflow mode actuator Motor lock X - C X (See DTC B1086:71 [MANUAL AIR CONDITIONER] .)
B13AA:71 - Air mix actuator Motor lock X - C X (See DTC B13AA:71 [MANUAL AIR CONDITIONER] .)
B13AB:12 - Air mix actuator (potentiometer) Circuit short to power supply X - C, D X (See DTC B13AB:12, B13AB:13 [MANUAL AIR CONDITIONER] .)
B13AB:13 - Circuit open X - C, D X
B1B71:11 - Evaporator temperature sensor Circuit short to ground X - C, D X (See DTC B1B71:11, B1B71:13 [MANUAL AIR CONDITIONER] .)
B1B71:13 - Circuit open X - C, D X
B1C1C:12 - Airflow mode actuator (potentiometer) Circuit short to power supply X - C, D X (See DTC B1C1C:12, B1C1C:13 [MANUAL AIR CONDITIONER] .)
B1C1C:13 - Circuit open X - C, D X
U0010:88 - CAN communication system Bus off X - C X (See DTC U0010:88, U0155:00 [MANUAL AIR CONDITIONER] .)
U0155:00 - Lost communication with instrument cluster No sub type information X - C, D X
U0423:68 - Invalid date received from Instrument cluster Event information X - C, D X (See DTC U0423:68 [MANUAL AIR CONDITIONER] .)
U200D:11 - Climate control unit circuit voltage (+5V) Circuit short to ground - - C, D X (See DTC U200D:11 [MANUAL AIR CONDITIONER] .)
U2300:54 - Configuration error Data not received X - C, D X (See DTC U2300:54, U2300:55, U2300:56, U2300:64 [MANUAL AIR CONDITIONER] .)
U2300:55 - Not configured X - C, D -
U2300:56 - Ineffective/non-interchangeable data read X - C, D X
U2300:64 - Error value read X - C, D X
U3003:16 - Climate control unit power supply voltage Power supply voltage decreases (10 V or less  ) - - C, D X (See DTC U3003:16, U3003:17 [MANUAL AIR CONDITIONER] .)
U3003:17 - Climate control unit power supply voltage Power supply voltage increases (17.3 V or more  ) - - C, D X
(1) C: CMDTC self test, D: ODDTC self test