Evaporative system test procedure
WARNING: This page is about a different car, the 2005 Mazda MPV. However, it is still accessible from the selected car via links, so may be relevant.
- Select the EVAP system test from the Toolbox on the WDS display and follow the instructions.
- Verify that all of the following PIDs are within the specifications at the pre-test confirmation screen.NOTE:
- To successfully perform this procedure, all PIDs must be within the following specifications before proceeding to the next step.
- Record the FTL_V and VPWR values.
- The PCM will cancel the EVAP system test if the VPWR PID value falls lower than 11.0 V during the test.
Specification
SPECIFICATION PID AND PID RANGEPID PID Range BARO 72.2 kPa {543 mmHg, 21.3 inHg} or more FTL_V 1.3-3.7 V LAF 5-40 °C{41- 104 °F} VPWR 11.0-14.5 V - Start the engine.
- Drive the vehicle or let the engine idle more than 20 min .
- Turn ignition switch off, then turn it to the ON position again (Key On Engine Off).
- Press the tick icon to start the test.
- Verify that each test result is indicated with green.
- If any test result is indicated with red, diagnose the problem using the following DTC troubleshooting procedure or component inspection procedure.
FAILED ITEM AND TROUBLESHOOTING
| Failed Item | Troubleshooting |
|---|---|
| Small leak | DTC P0442 |
| Very small leak (mA/S) | DTC P0456 |
| Very small leak (mA) | DTC P0456 |
| IMO | Inspect open or short to ground circuit between PCM and emission system leak detection pump |
| COV | Inspect change-over-valve to make sure it is not stuck closed |