Foreword [Multiplex Communication System]: Ms-Can
CAUTION:
- When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.
- When inspecting the DLC-2, touch it with a paper clip or similar thin pin without directly inserting a tester into the terminals.
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT MS-CAN LINE RESISTANCE
|
Yes | Go to the next step. |
| No | Go to Step 3. | ||
| 2 | INSPECT MS-CAN LINE FOR SHORT TO GROUND
|
Yes | Determine the location of the short to ground referring to "Determining Short to Ground Location" because a short to ground in the MS-CAN line can be considered the cause. (See DETERMINING SHORT TO GROUND LOCATION (MS-CAN) [MULTIPLEX COMMUNICATION SYSTEM] .) |
| No | Go to Step 4. | ||
| 3 | INSPECT MS-CAN LINE FOR OPEN CIRCUIT OR SHORT BETWEEN CIRCUITS
|
Yes | Go to Step 5. |
| No | Go to Step 6. | ||
| 4 | INSPECT MS-CAN LINE FOR OPEN OR SHORT CIRCUIT TO POWER SUPPLY
|
Yes | Determine the location of the open circuit referring to "Determining Open Circuit Location" because an open circuit in the MS-CAN line can be considered the cause. (See DETERMINING OPEN CIRCUIT LOCATION (MS-CAN) [MULTIPLEX COMMUNICATION SYSTEM] .) |
| No | Determine the location of the short circuit to the power supply referring to "Determining Short Circuit Location" because a short to ground in the MS-CAN line can be considered the cause. (See DETERMINING SHORT TO POWER SUPPLY LOCATION (MS-CAN) [MULTIPLEX COMMUNICATION SYSTEM] .) |
||
| 5 | INSPECT INSTRUMENT CLUSTER AND INFORMATION DISPLAY RESISTANCES
|
Yes | Determine the location of the open circuit referring to "Determining Open Circuit Location" because an open circuit in the MS-CAN line can be considered the cause. (See DETERMINING OPEN CIRCUIT LOCATION (MS-CAN) [MULTIPLEX COMMUNICATION SYSTEM] .) |
| No | Instrument cluster resistance has malfunction
Information display resistance has malfunction
|
||
| 6 | INSPECT MS-CAN LINE FOR OPEN CIRCUIT OR SHORT BETWEEN CIRCUITS
|
Yes | Determine the location of the short between circuits referring to "Determining Location of Short between Circuits" because a short between circuits in the MS-CAN line can be considered the cause. (See DETERMINING SHORT BETWEEN CIRCUITS LOCATION (MS-CAN) [MULTIPLEX COMMUNICATION SYSTEM] .) |
| No | Determine the location of the open circuit referring to "Determining Open Circuit Location" because an open circuit in the MS-CAN line can be considered the cause. (See DETERMINING OPEN CIRCUIT LOCATION (MS-CAN) [MULTIPLEX COMMUNICATION SYSTEM] .) |
||