Determination procedure
CAUTION:
- When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.
- When inspecting the DLC-2, touch it with a paper clip or similar thin pin without directly inserting a tester into the terminals.
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT CAN LINE IN BCM FOR SHORT TO GROUND
|
Yes | Replace the BCM because there is a short to ground in the BCM. (See BODY CONTROL MODULE (BCM) REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 2 | INSPECT CAN LINE BETWEEN BCM AND DLC-2 FOR SHORT TO GROUND
|
Yes | Go to the next step. |
| No | Go to Step 8. | ||
| 3 | INSPECT CAN LINE BETWEEN CONNECTOR C-18 AND INSTRUMENT CLUSTER FOR SHORT TO GROUND
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness between the BCM and connector C-18 because the wiring harness is shorted to ground. | ||
| 4 | INSPECT CAN-RELATED MODULES FOR SHORT TO GROUND
|
Yes | Go to the next step. |
| No | Replace the module in which there was no continuity when it was removed. | ||
| 5 | INSPECT CAN LINE BETWEEN DLC-2 AND CONNECTOR C-47 FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between DLC-2 and connector C-47 because the wiring harness is shorted to ground. |
| No | Go to the next step. | ||
| 6 | INSPECT CAN LINE BETWEEN SAS CONTROL MODULE AND CONNECTOR C-47 FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between SAS control module and connector C-47 because the wiring harness is shorted to ground. |
| No | Go to the next step. | ||
| 7 | INSPECT CAN LINE BETWEEN INSTRUMENT CLUSTER AND CONNECTOR C-47 FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the instrument cluster and connector C-47 because the wiring harness is shorted to ground. |
| No | Repair or replace the wiring harness between connector C-18 and connector C-47 because the wiring harness is shorted to ground. | ||
| 8 | INSPECT CAN LINE BETWEEN BCM AND CONNECTOR C-02 FOR SHORT TO GROUND
|
Yes | Go to the next step. |
| No | Go to Step 10. | ||
| 9 | INSPECT CAN-RELATED MODULES FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between connector C-02 and the BCM because the wiring harness is shorted to ground. |
| No | Replace the module in which there was no continuity when it was removed. | ||
| 10 | INSPECT CAN-RELATED MODULES FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between PCM and the connector C-02 because the wiring harness is shorted to ground. |
| No | Replace the module in which there was no continuity when it was removed. | ||