Diagnostic Procedure
WARNING: This page is about a different variant/trim than selected.
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record FREEZE FRAME DATA on the repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available Service Bulletins.
|
| No | Go to the next step. | ||
| 3 | INSPECT FOR POWER SUPPLY IN WIRING HARNESS
|
Yes | Switch the ignition to off. Go to the next step. |
| No | Inspect the ENGINE fuse.
Go to Step 9. |
||
| 4 | INSPECT HO2S HEATER FOR SHORT TO GROUND
|
Yes | Go to the next step. |
| No | Repair or replace suspected part, go to Step 9 | ||
| 5 | INSPECT HO2S HEATER FOR SHORT IN WIRING HARNESS
|
Yes | Go to the next step. |
| No | Repair or replace suspected part, go to Step 9 | ||
| 6 | INSPECT HO2S HEATER CIRCUIT FOR OPEN CIRCUIT IN WIRING HARNESS
|
Yes | Go to the next step. |
| No | Repair or replace suspected part, go to Step 9. | ||
| 7 | INSPECT INTERNAL RESISTANCE OF HO2S HEATER
|
Yes | Go to the next step. |
| No | Replace the suspect HO2S. (See HEATED OXYGEN SENSOR (HO2S) REMOVAL/INSTALLATION .) Go to Step 9. |
||
| 8 | INSPECT HO2S CASE FOR SHORT TO POWER SUPPLY, HTR, AND SIGNRTN
|
Yes | Go to the next step. (The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.) |
| No | Replace the suspect HO2S. (See HEATED OXYGEN SENSOR (HO2S) REMOVAL/INSTALLATION .) Go to the next step. |
||
| 9 | VERIFY TROUBLESHOOTING OF DTC P0054:00, P0060:00 HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
Go to the next step. |
| No | Go to the next step. | ||
| 10 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .) |
| No | Troubleshooting completed. | ||