LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2012 >> 6 i Touring >> Repair and Diagnosis >> External Pages >> Different car >> Section 590 (Refrigerant System [HVAC]) >> Refrigerant Charging >> Evacuation

Refrigerant Charging: Evacuation

WARNING: This page is about a different car, the 2009 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
  1. Open all the valves of the manifold gauge.
    CAUTION:
    • Close the manifold gauge valve immediately after stopping the vacuum pump. If the valve is left open, the vacuum pump oil will back flow into the refrigeration cycle and cause a decrease in the efficiency of the air conditioner.
  2. Start the vacuum pump and let it operate for 15 min.
    Fig 1: Identifying Manifold Gauge And Close Valve
    G06206051Courtesy of MAZDA MOTORS CORP.
  3. Verify that high- and low-pressure side readings of the manifold gauge are at -101 kPa {-760 mm Hg, -29.9 in. Hg}.  Close each valve of the manifold gauge.
    Fig 2: Identifying High- And Low-Pressure Readings Of Manifold Gauge
    G06206052Courtesy of MAZDA MOTORS CORP.