Diagnostic procedure
WARNING: This page is about a different variant/trim than selected.
NO. 30 DOES NOT DOWNSHIFT IN M POSITION (FS5A-EL) DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | DETERMINE IF MALFUNCTION CAUSE IS M POSITION SWITCH OR DOWN SWITCH
|
Yes | Go to> the next step. |
| No | Perform the symptom troubleshooting "M position indicator light dose not illuminate in M position/M position indicator light illuminate in D position". (See NO. 31 M POSITION INDICATOR LIGHT DOES NOT ILLUMINATE IN M POSITION/M POSITION INDICATOR LIGHT ILLUMINATES IN D POSITION .) |
||
| 2 | VERIFY IF MALFUNCTION CAUSE IS DOWN SWITCH SIGNAL OR INSTRUMENT CLUSTER
|
Yes | Inspect the instrument cluster. (See INSTRUMENT CLUSTER INSPECTION .) Replace the instrument cluster if necessary. (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .) |
| No | Inspect the down switch. (See DOWN SWITCH INSPECTION .) If the down switch is normal, inspect for continuity between the selector lever component terminal C and TCM terminal 2F. |
||
| 3 |
|
||