  1. Inspect for continuity of the diodes using an analog circuit tester.
    • If not as specified, replace the rectifier.

    Specification 

    CONTINUITY SPECIFICATIONS

    Negative Positive Continuity
    E P1, P2, P3, P4, P5, P6 Yes
    B No
    P1, P2, P3, P4, P5, P6 E No
    B Yes
    Fig 1: Diodes
    G06151001Courtesy of MAZDA MOTORS CORP.