LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2011 >> 6 s Touring Plus >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (On-Board Diagnostic [Engine Control System MZR 2.5]) >> DTC P0037:00 >> Diagnostic procedure

Diagnostic procedure

WARNING: This page is about a different variant/trim than selected.
DIAGNOSTIC PROCEDURE CHART

STEP INSPECTION ACTION
1 VERIFY FREEZE FRAME DATA (MODE 2)/SNAPSHOT DATA AND DIAGNOSTIC MONITORING TEST RESULTS HAVE BEEN RECORDED 
  • Have the FREEZE FRAME DATA (Mode 2)/snapshot data and DIAGNOSTIC MONITORING TEST RESULTS (A/F sensor heater, HO2S heater related) been recorded?
Yes Go to the next step.
No Record the FREEZE FRAME DATA (Mode 2)/snapshot data and DIAGNOSTIC MONITORING TEST RESULTS on the repair order, then go to the next step.
2 VERIFY RELATED REPAIR INFORMATION AVAILABILITY 
  • Verify related Service Bulletins and/or on-line repair information availability.
  • Is any related repair information available?
Yes Perform repair or diagnosis according to the available repair information.
  • If the vehicle is not repaired, go to the next step.
No Go to the next step.
3 INSPECT HO2S CONNECTOR CONDITION 
  • Switch the ignition to off.
  • Disconnect the HO2S connector.
  • Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
  • Is there any malfunction?
Yes Repair or replace the terminal and/or connector, then go to Step 9.
No Go to the next step.
4 INSPECT HO2S HEATER POWER SUPPLY CIRCUIT FOR SHORT TO GROUND OR OPEN CIRCUIT 
  • HO2S connector is disconnected.
  • Switch the ignition to ON (engine off).
  • Measure the voltage between HO2S terminal C (wiring harness-side) and body ground.
  • Is the voltage B+  ?
Yes Go to the next step.
No Inspect the HEGO 5 A fuse.
  • If the fuse is melt:
    • Repair or replace the wiring harness for a possible short to ground.
    • Replace the fuse.
  • If the fuse is deterioration:
    • Replace the fuse.
  • If the fuse is normal:
    • Repair or replace the wiring harness for a possible open circuit.

Go to Step 9.
5 INSPECT HO2S HEATER CONTROL CIRCUIT FOR SHORT TO GROUND 
  • HO2S connector is disconnected.
  • Switch the ignition to off.
  • Inspect for continuity between HO2S terminal D (wiring harness-side) and body ground.
  • Is there continuity?
Yes If the short to ground circuit could be detected:
  • Repair or replace the wiring harness for a possible short to ground.

    If the short to ground circuit could not be detected:

  • Replace the PCM (short to ground in PCM internal circuit).

(See PCM REMOVAL/INSTALLATION .)
Go to Step 9.
No Go to the next step.
6 INSPECT HO2S HEATER  Yes Replace the HO2S, then go to Step 9.
(See HEATED OXYGEN SENSOR (HO2S) REMOVAL/INSTALLATION .)
No Go to the next step.
7 INSPECT PCM CONNECTOR CONDITION 
  • Switch the ignition to off.
  • Disconnect the PCM connector.
  • Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
  • Is there any malfunction?
Yes Repair or replace the terminal and/or connector, then go to Step 9.
No Go to the next step.
8 INSPECT HO2S HEATER CONTROL CIRCUIT FOR OPEN CIRCUIT 
  • HO2S and PCM connectors are disconnected.
  • Inspect for continuity between HO2S terminal D (wiring harness-side) and PCM terminal 2B (wiring harness-side).
  • Is there continuity?
Yes Go to the next step.
No Repair or replace the wiring harness for a possible open circuit, then go to the next step.
9 VERIFY DTC TROUBLESHOOTING COMPLETED 
  • Make sure to reconnect all disconnected connectors.
  • Clear the DTC from the PCM memory using the M-MDS.

    (See AFTER REPAIR PROCEDURE .)

  • Perform the KOEO or KOER self test.

    (See KOEO/KOER SELF TEST .)

  • Is the PENDING CODE for this DTC present?
Yes Repeat the inspection from Step 1.
  • If the malfunction recurs, replace the PCM.

(See PCM REMOVAL/INSTALLATION .)
Go to the next step.
No Go to the next step.
10 VERIFY AFTER REPAIR PROCEDURE  Yes Go to the applicable DTC inspection.
(See DTC TABLE .)
No DTC troubleshooting completed.