LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2009 >> B4000 Standard >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Symptom Troubleshooting [Instrumentation/Driver Information) >> Horn >> Inspection and Verification

Inspection and Verification

  1. Verify the customer concern.
  2. Visually inspect the following for obvious signs of mechanical or electrical damage.
    VISUAL INSPECTION CHART

    Mechanical Electrical
    • Horn
    • Horn switch (part of the steering wheel)
    • Battery junction box (BJB) fuse 5 (50A)
    • Smart junction box (SJB) fuse 13 (15A)
    • Circuitry
    • Clockspring
    • BJB
    • SJB
  3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
    NOTE:
    • Make sure to use the latest scan tool software release.
  4. If the cause is not visually evident, connect the IDS or equivalent tester to the data link connector (DLC) and select the vehicle to be tested from the IDS or equivalent tester menu.
    NOTE:
    • The vehicle communication module (VCM) LED prove-out confirms power and ground from the DLC are provided to the VCM.
  5. If the IDS or equivalent tester does not communicate with the VCM:
  6. If the scan tool does not communicate with the vehicle:
  7. Carry out the network test:
  8. Clear the continuous DTCs and carry out the self-test diagnostics for the SJB.
  9. If the DTCs retrieved are related to the concern, See Smart Junction Box (SJB) Diagnostic Trouble Code (DTC) Index . For all other DTCs, see Diagnostic Trouble Code (DTC) Index - B, C And U Codes
  10. If no DTCs related to the concern are retrieved, see SYMPTOM TROUBLESHOOTING CHART - HORN  .