LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2008 >> B4000 Base, Automatic >> Repair and Diagnosis >> Engine Mechanical >> Mechanical >> Engine Mechanical [Intake-Air System] >> Air Cleaner Outlet Tube Removal / Installation - 4.0L

Air Cleaner Outlet Tube Removal / Installation - 4.0L

  1. Disconnect the crankcase ventilation tube and remove the mass airflow (MAF) sensor wiring harness push-pin.
    Fig 1: Locating Crankcase Ventilation Tube And Mass Airflow (MAF) Sensor Wiring Harness Push-Pin
    G04929960Courtesy of MAZDA MOTORS CORP.
  2. Loosen the hose clamps and remove the air cleaner outlet pipe.
    Fig 2: Hose Clamps And Air Cleaner Outlet Pipe Bolts With Torque Specifications
    G04929961Courtesy of MAZDA MOTORS CORP.
    NOTE:
    • Visually check the engine air cleaner intake duct and outlet tube for any foreign objects, obstructions or punctures.
  3. To install, reverse the removal procedure.