Normal Operation
The check fuel cap warning indicator is used to indicate significant leaks that exceed specifications in the fuel tank evaporative system following fuel system filling. The fuel tank pressure is monitored by the powertrain control module (PCM) and if a leak is detected it signals a fault by sending a message to the instrument cluster over the high speed controller area network (HS-CAN) communication bus. The instrument cluster illuminates the check fuel cap warning indicator. The instrument cluster sets DTC U0100 in continuous memory if the fuel tank pressure status message is missing for more than 5 seconds and the instrument cluster turns off the check fuel cap indicator.
This pinpoint test is intended to diagnose the following:
- PCM
- Instrument cluster
CHECK FUEL CAP WARNING INDICATOR PINPOINT TEST 9
| PINPOINT TEST 9 | THE CHECK FUEL CAP WARNING INDICATOR IS NEVER/ALWAYS ON | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | RETRIEVE THE RECORDED DTCs FROM BOTH THE CONTINUOUS AND ON-DEMAND PCM SELF-TESTS
|
Yes | See DIAGNOSTIC TROUBLE CODE (DTC) INDEX - POWERTRAIN CONTROL MODULE (PCM) . |
| No | Go to next step. | ||
| 2 | RETRIEVE THE RECORDED DTCs FROM BOTH THE CONTINUOUS AND ON-DEMAND INSTRUMENT CLUSTER SELF-TESTS
|
Yes | CLEAR the DTCs. REPEAT the self-test. If DTC U0100 is retrieved again, go to INSTRUMENT CLUSTER DIAGNOSTIC TROUBLE CODE (DTC) INDEX . |
| No | Go to next step. | ||
| 3 | CARRY OUT THE INSTRUMENT CLUSTER INDICATOR LAMP COMMAND USING THE SCAN TOOL
|
Yes | Go to next step. |
| No | Go to step 5. | ||
| 4 | CHECK FOR CORRECT PCM OPERATION
|
Yes | INSTALL a new PCM. See POWERTRAIN CONTROL MODULE (PCM) REMOVAL / INSTALLATION . TEST the system for normal operation. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. | ||
| 5 | CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION
|
Yes | INSTALL a new instrument cluster. See INSTRUMENT CLUSTER . TEST the system for normal operation. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. | ||