Diagnostic procedure
WARNING: This page is about a different car, the 2005 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
NO. 7 AIR FROM VENTS COLD ENOUGH DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | INSPECT DRIVE BELT
|
Yes | Go to next step. |
| No | Adjust or replace drive belt, then go to Step 20. | ||
| 2 | INSPECT REFRIGERANT SYSTEM PERFORMANCE
|
Yes | Operation is normal. (Recheck malfunction symptoms.) |
| No | Go to next step. | ||
| 3 | CHECK TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT INTAKE AND CONDENSER OR ELSEWHERE
|
Yes | Go to next step. |
| No | Go to Step 6. | ||
| 4 | INSPECT BLOWER UNIT INTAKE
|
Yes | Remove obstruction, then go to Step 20. (If air does not reach evaporator within A/C unit, heat exchange does not occur and refrigerant pressure becomes high. Therefore, removal of obstruction is necessary.) |
| No | Go to next step. | ||
| 5 | INSPECT CONDENSER
|
Yes | Adjust refrigerant to specified amount, then go to Step 20. (Excessive amount of refrigerant.) |
| No | Replace condenser, or repair and clean condenser fins, then go to Step 20. | ||
| 6 | CHECK TO SEE WHETHER MALFUNCTION IS IN EXPANSION VALVE, RECEIVER/DRIER AND REFRIGERANT LINES OR ELSEWHERE
|
Yes | Go to next step. |
| No | Go to Step 14. | ||
| 7 | CHECK TO SEE WHETHER MALFUNCTION IS IN EXPANSION VALVE AND RECEIVER/DRIER OR ELSEWHERE
|
Yes | Go to next step. |
| No | Go to Step 10. | ||
| 8 | CHECK TO SEE WHETHER MALFUNCTION IS IN EXPANSION VALVE OR RECEIVER/DRIER
|
Yes | Go to next step. |
| No | Replace condenser and bleed refrigerant line for 30 min or more using a vacuum pump, add refrigerant to specified level, then go to Step 20. (Since water has intermixed in receiver/drier and it is saturated, replacement is necessary.) | ||
| 9 | VERIFY THAT EXPANSION VALVE HEAT-SENSING TUBE WITHIN A/C UNIT IS POSITIONED SECURELY AND CORRECTLY
|
Yes | Replace expansion valve, then go to Step 20. (Since valve closes too much, replacement is necessary.) |
| No | Install heat-sensing tube securely in proper position, then go to Step 20. | ||
| 10 | INSPECT REFRIGERANT LINES
|
Yes | Go to next step. |
| No | If piping or A/C component(s) are damaged or cracked, replace them. Then go to Step 20. If there is no damage, go to Step 13. |
||
| 11 | INSPECT EVAPORATOR PIPING CONNECTIONS IN A/C UNIT FOR GAS LEAKAGE
|
Yes | If the vane makes a noise, add 10 ml {10 cc, 0.34 fl oz}
of compressor oil to the A/C compressor. Verify that the noise is no longer heard. Adjust refrigerant to specified amount, then go to Step 20. |
| No | If piping is damaged or cracked, replace it. Then go to Step 20. If there is no damage, go to next step. |
||
| 12 | INSPECT EVAPORATOR PIPING CONNECTIONS IN A/C UNIT FOR LOOSE
|
Yes | Tighten connections with specified torque, adjust both compressor oil and refrigerant to specified amount, then go to Step 20. |
| No | If the vane makes a noise, add 10 ml {10 cc, 0.34 fl oz}
of compressor oil to the A/C compressor. Verify that the noise is no longer heard. Replace O-ring on piping, adjust refrigerant to specified amount, then go to Step 20. |
||
| 13 | INSPECT PIPING CONNECTIONS FOR LOOSENESS
|
Yes | Tighten connections with specified torque, adjust both compressor oil and refrigerant to specified amount, then go to Step 20. |
| No | If the vane makes a noise, add 10 ml {10 cc, 0.34 fl oz}
of compressor oil to the A/C compressor. Verify that the noise is no longer heard. Replace O-ring on piping, adjust refrigerant to specified amount, then go to Step 20. |
||
| 14 | CHECK TO SEE WHETHER MALFUNCTION IS IN EXPANSION VALVE, AIR MIX ACTUATOR AND COMPRESSOR OIL OR ELSEWHERE
|
Yes | Go to next step. (Pressure increases only a little.) |
| No | Go to Step 17. | ||
| 15 | CHECK TO SEE WHETHER MALFUNCTION IS IN COMPRESSOR OIL AMOUNT AND A/C COMPRESSOR OR ELSEWHERE
|
Yes | Return to Step 3. |
| No | Go to next step. | ||
| 16 | CHECK TO SEE WHETHER MALFUNCTION IS IN COMPRESSOR OIL AMOUNT OR A/C COMPRESSOR
|
Yes | Troubleshooting completed. (Explain to customer that cause was insufficient compressor oil.) |
| No | Replace A/C compressor, then +go to Step 20. (Cause is defective A/C compressor.) | ||
| 17 | CHECK TO SEE WHETHER MALFUNCTION IS IN EXPANSION VALVE OR ELSEWHERE
|
Yes | Go to Step 19. |
| No | Go to next step. | ||
| 18 | VERIFY THAT AIR MIX IS INSTALLED SECURELY AND PROPERLY
Turn A/C switch on. Set FRESH mode. Set temperature control to MAX COLD. Set VENT mode.
|
Yes | Set fan switch to the maximum position. |
| No | Repair or install links, cranks and rods securely in proper position, then go to Step 20. | ||
| 19 | VERIFY THAT EXPANSION VALVE HEAT-SENSING TUBE WITHIN A/C UNIT IS POSITIONED SECURELY AND CORRECTLY
|
Yes | Replace expansion valve, then go to next step. (Since valve opens too much, replacement is necessary.) |
| No | Install heat-sensing tube securely in proper position, then go to next step. | ||
| 20 | VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR
|
Yes | Troubleshooting completed. Explain repairs to customer. |
| No | Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs. | ||