Possible Causes
- circuit (V/O) open
- SJB
- instrument cluster
CAUTION:
- Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
DOOR AJAR WARNING INDICATOR IS INOPERATIVE - PINPOINT TEST REFERENCE
| PINPOINT TEST 17 | DOOR AJAR WARNING INDICATOR IS INOPERATIVE | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK THE INTERIOR LAMPS FOR CORRECT OPERATION
|
Yes | Go to next step. |
| No | See INTERIOR LIGHTING , to continue diagnosis on the interior lamps. | ||
| 2 | CHECK THE DRIVER DOOR INPUT TO THE CLUSTER
|
Yes | Go to next step. |
| No | Go to step 5. | ||
| 3 | RETRIEVE THE RECORDED DTCs FROM BOTH THE CONTINUOUS AND ON-DEMAND SJB SELF-TESTS
|
Yes | If DTC U0140 is retrieved, CLEAR the DTCs. REPEAT the self-tests. If DTC U0140 is retrieved again, INSTALL a new SJB. See SMART JUNCTION BOX (SJB) , . For all other DTCs, see DIAGNOSTIC TROUBLE CODE (DTC) INDEX - B, C AND U CODES , . |
| No | Go to next step. | ||
| 4 | CARRY OUT THE INSTRUMENT CLUSTER WARNING LAMP AND CHIME ACTIVE COMMAND USING THE SCAN TOOL
|
Yes | Go to step 7. |
| No | Go to step 8. | ||
| 5 | CHECK THE SJB FOR AN OPEN
|
Yes | Go to step 7. |
| No | Go to next step. | ||
| 6 | CHECK CIRCUIT (V/O) FOR AN OPEN
|
Yes | Go to step 8. |
| No | Repair the circuit. Test the system for normal operation. | ||
| 7 | CHECK FOR CORRECT SJB OPERATION
|
Yes | Install a new SJB. See SMART JUNCTION BOX (SJB) , . Test the system for normal operation. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. | ||
| 8 | CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION
|
Yes | Install a new instrument cluster. see INSTRUMENT CLUSTER . Test the system for normal operation. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. | ||