LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2007 >> B2300 Standard >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Troubleshooting (Instrumentation/Driver Information) >> Pinpoint Test 13: RH Turn Signal Indicator Is Never On >> Possible Causes

Possible Causes

CAUTION:
  • Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
RH TURN SIGNAL INDICATOR IS NEVER ON - PINPOINT TEST REFERENCE

PINPOINT TEST 13 RH TURN SIGNAL INDICATOR IS NEVER ON
STEP INSPECTION ACTION
1 CHECK THE RH TURN SIGNAL OPERATION
  • Key ON.
  • Operate the RH turn signal.
  • Does the RH turn signal operate? 
Yes Go to next step.
No See TURN SIGNAL AND HAZARD LAMPS , to continue diagnosis of the turn signals.
2 CHECK CIRCUIT (GY/Y) FOR VOLTAGE
  • Key OFF.
  • Disconnect: Instrument cluster 0922-102.
  • Key ON.
  • Place the multifunction switch in the RH turn signal position.
  • Measure the voltage between the instrument cluster 0922-102 pin 13, circuit (GY/Y), harness side and ground.
  • Does the voltage vary from 0 to greater than 10 volts? 
Yes Go to next step.
No Repair circuit (GY/Y) for an open. Test the system for normal operation.
3 CHECK THE GROUND TO THE INSTRUMENT CLUSTER
  • Key OFF.
  • Measure the resistance between the instrument cluster 0922-102 pin 1, circuit (B/Y), harness side and ground.
  • Is the resistance less than 5 ohms? 
Yes Go to next step.
No Repair the circuit. Test the system for normal operation.
4 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION
  • Disconnect all the instrument cluster connectors.
  • Check for:
    • corrosion
    • damaged pins
    • pushed-out pins
    • incorrectly installed bulb sockets
    • burnt-out bulbs
  • Connect all the instrument cluster connectors and make sure they seat correctly.
  • Operate the system and verify the concern is still present.
  • Is the concern still present? 
Yes Install a new instrument cluster. see INSTRUMENT CLUSTER . Test the system for normal operation.
No The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.