Possible Causes: Notes
- fuse(s)
- circuit (R) open
- circuit (V/GY) open
- circuit (B/W) open
- circuit (Y/O) open
- circuit (B/Y) open
- instrument cluster
CAUTION:
- Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
NO COMMUNICATION WITH THE INSTRUMENT CLUSTER - PINPOINT TEST REFERENCE
| PINPOINT TEST 1 | NO COMMUNICATION WITH THE INSTRUMENT CLUSTER | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK THE INSTRUMENT CLUSTER VOLTAGE SUPPLY
|
Yes | Go to step 2. |
| No | Verify the SJB fuses 9 (5A), 10 (10A), and 33 (5A) are OK. If OK, repair the circuit(s) in question. Test the system for normal operation. | ||
| 2 | CHECK THE INSTRUMENT CLUSTER GROUND CIRCUITS FOR AN OPEN
|
Yes | See COMMUNICATIONS NETWORK , . |
| No | Repair the circuits) in question. Test the system for normal operation. | ||