LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2006 >> B4000 Base, Automatic >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Control System [HVAC] >> Blend Door Actuator Removal / Installation

Blend Door Actuator Removal / Installation

  1. Remove the passenger air bag module. See PASSENGER AIR BAG MODULE .
  2. Remove the defroster opening grill.
    Fig 1: Removing/Installing Defroster Opening Grill
    G04309914Courtesy of MAZDA MOTORS CORP.
  3. Detach and position the RH demister hose aside.
    Fig 2: Positioning RH Demister Hose Aside
    G04309915Courtesy of MAZDA MOTORS CORP.
  4. Working through the opening near the RH defroster nozzle, remove the screw.
    Fig 3: Identifying RH Defroster Nozzle
    G04309916Courtesy of MAZDA MOTORS CORP.
  5. Remove the temperature blend door actuator.
    1. Disconnect the electrical connector.
    2. Remove the screws and the temperature blend door actuator.
    Fig 4: Removing/Installing Temperature Blend Door Actuator
    G04309917Courtesy of MAZDA MOTORS CORP.
  6. To install, reverse the removal procedure.