Possible Causes: Notes
- fuse(s)
- circuit (B) open
- circuit (P/B) open
- circuit (B/W) open
- circuit (R/Y) open
- circuit (B/LG) open
- instrument clusterCAUTION:
- Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
INSTRUMENT CLUSTER INOPERATIVE PINPOINT TEST REFERENCE
| PINPOINT TEST 22 | INSTRUMENT CLUSTER IS INOPERATIVE | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK THE INSTRUMENT CLUSTER FOR VOLTAGE
|
Yes | Go to next step. |
| No | Verify the SJB fuses 9 (5A), 10 (10A), and 33 (5A) are OK. If OK, repair the circuit in question for an open. Test the system for normal operation. | ||
| 2 | CHECK CIRCUITS (B/W) AND (B) FOR AN OPEN
|
Yes | Go to next step. |
| No | Repair circuit (B/W) or (B) for an open. Test the system for normal operation. | ||
| 3 | CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION
|
Yes | Install a new instrument cluster. See INSTRUMENT CLUSTER . Test the system for normal operation. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. | ||