Possible Causes
- circuit (B/P) open
- instrument clusterCAUTION:
- Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
HEADLAMP ON WARNING CHIME DOES NOT OPERATE CORRECTLY PINPOINT TEST REFERENCE
| PINPOINT TEST 2 | HEADLAMP ON WARNING CHIME DOES NOT OPERATE CORRECTLY | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK THE INSTRUMENT CLUSTER IGNITION SWITCH PID
|
Yes | Go to next step. |
| No | See PINPOINT TEST 1: KEY-IN-IGNITION WARNING CHIME DOES NOT OPERATE CORRECTLY . | ||
| 2 | VERIFY THE INTERIOR LAMPS OPERATE CORRECTLY
|
Yes | Go to next step. |
| No | See INTERIOR LIGHTING to continue diagnosis of the interior lamps. | ||
| 3 | VERIFY THE EXTERIOR LAMPS OPERATE CORRECTLY
|
Yes | Go to next step. |
| No | See EXTERIOR LIGHTING to continue diagnosis of the exterior lamps. | ||
| 4 | CHECK CIRCUIT (B/P) FOR VOLTAGE
|
Yes | Go to next step. |
| No | Repair circuit (B/P) for an open. Test the system for normal operation. | ||
| 5 | CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION
|
Yes | Install a new instrument cluster. See INSTRUMENT CLUSTER . Test the system for normal operation. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. | ||