Open Circuit Inspection
WARNING: This page is about a different variant/trim than selected.
- Inspect the following circuit for open.
- Power circuit (VSS connector terminal A to main relay terminal D)
- Ground circuit (VSS connector terminal C to GND)
- If an open circuit or short circuit is found, repair the malfunctioning wiring harness.
- If there are no open or short circuits, perform the sensor rotor inspection.