Air Bypass Valve Inspection
WARNING: This page is about a different variant/trim than selected.
- Remove the air bypass valve. (See INTAKE AIR SYSTEM REMOVAL/INSTALLATION ).
- Connect the vacuum pump to the vacuum ports of the air bypass valve.
Approx value
- Verify that the airflow is as indicated in the table.
- If there is any malfunction, replace the air bypass valve.
VACUUM VALVE OPERATION REFERENCEVacuum (kPa {mmHg, inHg}) Valve operation condition Airflow between port A-B -66 {-496, -20} or more Open Yes -49 {-367, -14} or less Closed No