Cooling Fan Motor Inspection
WARNING: This page is about a different variant/trim than selected.
NOTE:
- Cooling fan motor No.2 can be inspected, however, cooling fan motor No.1 cannot be inspected because it is integrated with the fan control module.
- Verify that the battery is fully charged, (See BATTERY INSPECTION [L3 WITH TC] ).
- Disconnect the cooling fan motor No.2 connector (2 terminals).
- Install a tester and battery to the cooling fan motor No.2 connector (2 terminals) as shown in the figure.
- Verify that fan motor No.2 operates smoothly at the standard current.
- If not within the specification, replace the fan motor No.2.
Cooling fan motor No.2 current 12.8-16.8 A