Idle Speed Inspection
WARNING: This page is about a different variant/trim than selected.
NOTE:
- Idle rotation cannot be adjusted.
- Warm up the engine.
- Turn off all electrical loads.
- Increase the engine speed to 2,500-3,000 RPM until the cooling fan starts running.
- When the cooling fan starts running, release the accelerator pedal and wait until the cooling fan stops running.
- Connect the SST (WDS or equivalent) to the DLC-2.
- Verify that the engine speed (WDS: RPM) is as follows using the PID/data monitor function of the SST (WDS or equivalent)
as follows:
Idle speed No load 650-750
Idle-up speed (RPM)
Electrical load on *1 650-750
P/S operation 650-750
A/C operation (medium-pressure switch off) 700-800
A/C operation (medium-pressure switch on) 725-825
*1 : When the following electrical loads are on: Headlights, rear defroster, cooling fan No. 1, cooling fan No. 2, and the blower motor (2-step or more).