NO. 3 AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 INSPECT BLOWER SYSTEM 
  • Inspect the following systems and electrical parts:
    • Blower relay
    • Blower motor
    • Resistor
    • Fan switch
    • Related wiring harnesses
  • Are they okay?
Yes Go to next step.
No Repair or replace malfunctioning part, then go to Step 5.
2 CHECK TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR ELSEWHERE 
  • Turn ignition switch to ON position.
  • Turn fan switch on.
  • Recirculate air inside vehicle.
  • Does fan in blower unit rotate smoothly?
Yes Go to Step 4.
No Go to next step.
3 INSPECT BLOWER UNIT 
  • Inspect fan in blower unit.
    • Is fan free of interference from blower unit case?
    • Is fan free of foreign material and obstructions?
  • Is fan okay?
Yes Go to next step.
No Remove obstruction, repair or replace fan and blower unit case, then go to Step 5.
4 INSPECT BLOWER UNIT INTAKE VENT 
  • Is blower unit intake vent clogged?
Yes Remove obstruction, then go to next step.
No Inspect if there are any obstructions in passage between blower unit and A/C unit, then go to next step.
5 VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR 
  • Does air blow out?
Yes Troubleshooting completed.
Explain repairs to customer.