Diagnostic procedure
WARNING: This page is about a different car, the 2005 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
- When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, check to make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.
NO. 2 AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | INSPECT BLOWER 40 A FUSE
|
Yes | Go to next step. |
| No | Replace fuse, then go to Step 15. If fuse burns out immediately, go to next step. | ||
| 2 | INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR ELSEWHERE
|
Yes | Go to next step. |
| No | Go to Step 4. | ||
| 3 | INSPECT BLOWER UNIT INTAKE VENT
|
Yes | Remove obstruction, then go to Step 15. |
| No | Inspect if there are any obstructions in passage between blower unit to A/C unit, then go to Step 15. | ||
| 4* | INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER RELAY SYSTEM OR PWM UNIT SYSTEM
|
Yes | Go to Step 8. |
| No | Go to next step. | ||
| 5* | INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN FUSE BLOCK AND BLOWER RELAY) OR ELSEWHERE
|
Yes | Go to next step. |
| No | Repair wiring harness between blower relay and BLOWER 40 A fuse, then go to Step 15. | ||
| 6* | INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND GROUND) OR ELSEWHERE
|
Yes | Go to next step. |
| No | Repair wiring harness between blower relay and ground, then go to Step 15. | ||
| 7* | INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND BLOWER MOTOR) OR BLOWER RELAY
|
Yes | Repair wiring harness between blower relay and blower motor, then go to Step 15. |
| No | Replace blower relay, then go to Step 15. | ||
| 8* | INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER MOTOR OR ELSEWHERE
|
Yes | Go to next step. |
| No | Inspect blower motor, then go to Step 15. | ||
| 9* | INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER MOTOR AND PWM UNIT) OR ELSEWHERE
|
Yes | Go to next step. |
| No | Repair wiring harness between blower motor and PWM unit, then go to Step 15. | ||
| 10* | INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN PWM UNIT AND GROUND) OR ELSEWHERE
|
Yes | Go to next step. |
| No | Repair wiring harness between PWM unit and ground, then go to Step 15. | ||
| 11 | INSPECT BLOWER UNIT
|
Yes | Go to next step. |
| No | Remove obstruction, repair or replace fan and blower unit case, then go to Step 15. | ||
| 12* | INSPECT TO SEE WHETHER MALFUNCTION IS IN PWM UNIT OR ELSEWHERE
|
Yes | Replace PWM unit, then go to Step 15. |
| No | Go to next step. | ||
| 13* | INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN PWM UNIT AND CLIMATE CONTROL UNIT) OR ELSEWHERE
|
Yes | Go to next step. |
| No | Repair wiring harness between PWM unit and climate control unit, then go to Step 15. | ||
| 14* | INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR WIRING HARNESS (SHORT TO GROUND BETWEEN PWM UNIT AND CLIMATE CONTROL UNIT)
|
Yes | Repair wiring harness between PWM unit and ground, then go to next step. |
| No | Replace climate control unit, then go to next step. | ||
| 15 | CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
|
Yes | Troubleshooting completed. Explain repairs to customer. |
| No | Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs. | ||