LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2002 >> Tribute LX, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 64 (Engine Controls [System & Component Testing]) >> Miscellaneous Controls >> Cooling Fan >> Single Speed Motor - Miata, Protege & Protege5

Single Speed Motor - Miata, Protege & Protege5

WARNING: This page is about a different car, the 2003 Mazda Protege5, 2003 Mazda Protege, 2003 Mazda MX-5 Miata, 2003 Mazda MPV, and 2003 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ensure battery is fully charged. Disconnect cooling fan motor 2-pin harness connector. Connect ammeter between positive battery terminal and positive terminal of cooling fan motor connector. See Fig 1 or Fig 2 . Ground negative cooling fan terminal. See appropriate WIRING DIAGRAM in ELECTRIC COOLING FANS article in ENGINE COOLING.
  2. Ensure cooling fan motor operates smoothly at specified standard current draw. See COOLING FAN MOTOR CURRENT DRAW SPECIFICATIONS  table. If cooling fan motor current draw is not as specified, replace cooling fan motor.
COOLING FAN MOTOR CURRENT DRAW SPECIFICATIONS

Application Amps
MAZDA6
2.3L 8.5-11.5
3.0L 11.8-14.8
Miata 4.5-6.49
MPV 12.0-15.0
Protege & Protege5
With A/T 5.2-7.2
With A/T & Traction Control 8.5-11.5
With M/T 2.4-4.4
Fig 1: Testing Single Speed Cooling Fan Motor - Miata
G00193587Courtesy of MAZDA MOTORS CORP.
Fig 2: Testing Single Speed Cooling Fan Motor - Protege & Protege5
G00193588Courtesy of MAZDA MOTORS CORP.